SPECIFICATIONS |
| Real-time block |
| CRT | |
| Type | 150mm rectangular, with internal graticule |
| Accelerating voltage | Approx. 17kV |
| Effective area | 8div. ?10div. (1div=10mm) |
| Vertical axis (Common for CH1, CH2) | |
| Operating modes | CH1, CH2, ADD, ALT, CHOP |
| Sensitivity | 1mV/div., 2mV/div. : ? 5% 5mV/div. to 5V/div. : ?2% |
| Attenuator | 1mV/div. to 5V/div., 1-2-5 step, (fine adjustment) |
| Input impedance | 1MΩ?1%, approx. 20pF |
| Frequency response | DC | DC to 100MHz, (-3dB)(5mV/div to 5V/div.) DC to 20MHz, (-3dB)(1mV/div, 2mV/div.) |
| AC | 5Hz to 100MHz, (-3dB)(5mV/div to 5V/div.) 5Hz to 20MHz, (-3dB)(1mV/div to 2mV/div.) |
| Rise time | Approx. 3.5ns (5mV/div. to 5v/div.) Approx. 17.5ns (1mV/div., 2mV/div.) |
| Signal delay time | Can confirm the leading edge with the square wave that has a rise time less than the unit. |
| Crosstalk | Below -40dB (at 1kHz) |
| Polarity inversion | CH2 only |
| CHOP Frequency | Approx. 250kHz |
| Maximum input voltage | 800Vp-p or 400V (DC AC peak) |
| Horizontal axis | |
| Operating modes | Set to X-Y mode by H MODE CH1 : Y-axis、CH2 : X-axis |
| Sensitivity | 1mV/div, 2mV/div : ? 5%, 5mV/div to 5V/div : ?3% |
| Input impedance | Same as Vertical axis (CH2) |
| Frequency response | DC | DC to 1MHz, (-3dB) |
| AC | 5Hz to 1MHz, (-3dB) |
| X-Y phase difference | Below 3 degrees at 100kHz |
| Maximum input voltage | Same as vertical axis (CH2) |
| Sweep | |
| Sweep modes | A sweep. B sweep, ALT |
| Sweep time | A | 0.5s/div to 50ns/div ?2% in 1-2-5 steps, 22 ranges, and fine adjustment |
| B | 50ms/div to 50ns/div ?2% in 1-2-5 steps, 19 ranges |
| Magnified sweep | ?10 ?5% ( ?8% less than 0.5譻/div) |
| Linearity | ?3% (10MAG ? 5%) |
| Delay mode | Continuous delay, triggered delay |
| Delay time | 0.5s/div to 50ns/div ; continuously variable from 0.2div.~10div. |
| Delay time error | ?(3% of set value 1% of f.s.) (0 to 300ns) |
| Delay jitter | 10,000 : 1 of 10 times of the A sweep time |
| Hold off | A Sweep : Continuously variable from NORM
|
| Trace separation | B separation from A is continuously adjustable to approx. ?4 div. |
| Triggering | |
| Trigger sources | VERT, CH1, CH2, LINE, EXT |
| Mode | AUTO, NORM, FIX, SINGLE |
| Trigger coupling | AC, HFrej, DC, TV-FRAME, TV-LINE |
| Trigger sensitivity | |
| Trigger coupling | Synced frequency range | Internal sensitivity | External sensitivity |
| NORM | FIX | NORM | FIX |
| DC | DC to 50MHz | 1div. | 1.5div. | 100mV | 150mV |
| 50MHz to 100MHz | 1.5div. | 2div. | 150mV | 200mV |
| AC | 10Hz to 50MHz | 1div. | 1.5div. | 100mV | 150mV |
| 50MHz to 100MHz | 1.5div. | 2div. | 150mV | 200mV |
| HFrej | Minimum triggering amplitude increases above 10kHz |
| TV | TV-F, TV-L Comp.video | 1.5div. | 1.5div. | 150mV | 150mV |
| Calibration voltage | 1Vp-p ?1% 1kHz ? 0.1% |
| External trigger | |
| Input impedance | 1MΩ ?%, approx. 20pF |
| Max. input voltage | 100Vp-p or 50V (DC AC Peak, 1kHz or less) |
| CH1 Signal output | |
| Output voltage | Approx. 50mVp-p/div |
| Output impedance | Approx. 50Ω |
| Frequency response | 5mV to 5V/div. : 100Hz to 100MHz (-3dB) 1mV to 2mV/div. : 100Hz to 20MHz (-3dB) |
| Trace rotation | Enables trace rotation adjustment by semi-fixed controller on the panel |
| Storage block *Note : [ ] dual channel. |
| Vertical axis | |
| Vertical resolution | 8bit (25dot/div.) |
| Dynamic range | ?5div |
| Effective storage frequency | DC | DC to 40 MHz [16MHz] (sine interpolation) |
| AC | 5Hz to 40 MHz [16MHz] (sine interpolation) |
| Effective rise time | Below 16ns [40ns] (With linear interpolation) |
| frequency response | DC | DC to 40MHz (- 3dB) (5mV/div to 5V/div) DC to 20MHz (- 3dB) (1mV/div, 2mV/div) |
| AC | 5Hz to 40MHz (- 3dB) (5mV/div to 5V/div) 5Hz to 20MHz (- 3dB) (1mV/div, 2mV/div) |
| Memory capacity | |
| NORM sampling | |
Display memory (data) | 2 KW/CH (200dot/div) |
Display memory (REF) | 2 KW/CH |
Acquisition memory | 16KW/CH |
REF memory | 2 KW/CH |
| Roll mode | |
Display memory (data) | 2KW/CH (200dot/div.) |
Display memory (REF) | 2KW/CH |
Acquisition memory | 16KW/CH |
REF memory | 2KW/CH |
| Memory backup | Battery backed up for approx. 30,000 hrs. (at normal temperature) |
Acquisition memory | 16KW/CH |
REF memory | 2KW/CH |
| Sweep time・Display mode | |
| NORM sampling | 50ns/div. to 500s/div.(50ns/div. to 1譻 [2譻]/div. in the MAG range) (Maximum sampling rate : 100MS/s [40MS/s]) |
| Peak detector | 10譻/div. to 500s/div. |
| Roll mode | 0.2s/div. to 500s/div. |
| Storage mode | |
| AUTO | Same as NORM for the same period, free-running data updating in other cases. |
| NORM | Data updated each time an acceptable trigger is received. |
| SINGLE | Data is storaged with the first acceptable triggering after resetting and held |
| AVG (Averaging) | Average of 4 or 16 or 64 times |
| SMT (Smoothing) | Data writing point will be averaged following 32 words. |
| PST (Persistence) | Mutual display of maximum and minimum values in storage, and initialization by PST RESET. |
| PEAK | 25ns glitch detection |
| ROLL | NORM | Continuous recording and updating of data on the CRT. |
| SINGLE | After receiving the acceptable trigger, the pre-triggering data is updated and the data is stored. |
| Magnification, Compression | |
| Magnification | By pressing ?10 MAG under Hold conditions, 10-times magnification is obtained by linear interpolation around the CRT center. |
| Interpolation | Linear interpolation, sign interpolation |
| Trigger・Delay | |
| Pre-trigger | NORM | 0 to 10 div., 0 to 80 div (at 16KW/CH) (in 2.5div steps) |
| ROLL-SINGLE | 0div. to 80div.(in 2.5div steps) |
| X-Y | |
| Effective storage frequency range | DC to 16MHz (-3dB Adjustable sampling rate for the SWEEP TIME /DIV.) |
| External clock | Carries out sampling by first transition of signals input from the external clock terminal when setting SWEEP TIME/DIV to EXT. |
| Input impedance | Approx. 10kΩ |
| Maximum input voltage | 84Vp-p or 42V (DC AC peak, 1kHz or below) |
| Input signal level | TTL ";L"; level : 0.8V or less ";H"; level : 2.7V or more |
| Input signal frequency range | DC to 10MHz (1 kHz in roll mode) |
| Input signal duty ratio | 20% to 80% (DC to 5MHz) 40% to 60% (5MHz to 10MHz) |
| Waveform calculation | , - |
| Readout block |
| Panel setup value | CH1/CH2 scale factor (with probe detector), V-UNCAL, ADD, INVERT, A/B Sweep scale factor (MAG calculation, "*" displayed in MAG mode), Sweep-UNCAL, DELAY TIME, B TRIG'D, X-Y, Sampling waveform in X-Y mode, Display scroll, setup value storage function, Pre-trigger point, REF memory setup condition, Menu, OUTPUT |
| Cursor measurement (ΔV1 only in X-Y mode) | ΔV1 : Voltage display calculated using CH1 scale factor ΔV2 : Voltage display calculated using CH2 scale factor ΔT : Time display calculated using A sweep scale factor Δ1/T : Frequency display calculated using A sweep scale factor |
| VOLTS/DIV or TIME/DIV UNCAL mode | RATIO | Voltage ratio/Time ratio display using 5 div. of screen readout as 100% |
| PHASE | Phase difference display using 5 div. of screen readout as 360?/td> |
| Resolution/Measurement accuracy | 10 bits /? 4% |
| Measurement range | Vertical ?3.6 div. minimum from CRT center Horizontal ?4.6 div. minimum from CRT center |
| Parameter auto measurement | Each parameter is measured and displayed for the selected signal as the sync signal source from either CH1 or CH2 |
| Frequency (FRQ) | Mode selectable in Cursor mode. Measurement/display calculated by internal counter |
| Frequency range | 2 Hz to 100 MHz |
| Effective digits/Accuracy | 3 digits / 0.01% ?1 digit |
| Measurement sensitivity | Same as trigger sensitivity |
| Period (PER) | Mode selectable in Cursor mode. Measurement/display calculated by internal counter |
| Measurement range | 0.5 s to 10 ns |
| Effective digits/Accuracy | 3 digits / 0.01% ?1 digit |
| Measurement sensitivity | Same as trigger sensitivity |
| AC voltage (Vp-p) | Mode selectable in cursor mode. Peak-to-peak voltage measurement /display |
| Measurement range | 0.5 div. -- within effective screen area |
| Frequency range | 10 Hz to 100 kHz |
| Effective digits/Accuracy | 3 digits / 10 Hz to 40 Hz: ?{8% attenuator setup value V/div.) ?0.04 div.}, 40 Hz to 100 kHz: ?{3% attenuator setup value (V/div.) ?0.04 div.} |
| DC voltage (DCV) | Mode selectable in cursor mode. Average DC voltage measurement /display |
| Sensitivity | 0.5 div. -- within effective screen area |
| Effective digits/Accuracy | 3 digits / ?{3% atte-nuator setup value (V/div.) ?0.04 div.} |
| Auto setup | Automatically setup of Vertical axis attenuator, Sweep range, Vertical position, Horizontal position values for CH1 and CH2 |
| Period | 1.5 to 5 periods (H.VARIABLE CAL mode, with input signal up to 10 MHz) |
| Amplitude | Within effective screen area (within 1/2 of effective screen area in 2-channel mode) |
| Frequency (sine wave) | 50 Hz to 100 MHz |
| Position | Vertical axis: Almost at CRT center in single phenomenon mode. 2-channel mode: Approx. 2 div. (CH1), approx. -2 div. (CH2) from the CRT center. Horizontal axis: Starts from the left end of on-screen scale |
| Program step | Max. 100 steps (can be divided up to 5 groups) |
| Backup | Panel setup values are backed up by built-in battery. Battery life: Approx. 30,000 hours (in room temperature). Factory-default values resume when built-in battery is expired. |
| Power Supply block & Others |
| Power requirements & input voltage/Frequency | AC 100/120/220/230 V (? 10% as input fluctuation), 50/60 Hz |
| Power consumption (AC 100 V input) | Max. 77 W, 94 VA |
| Insulating voltage | AC 1.5 kV, 1 minute |
| Insulating resistance | 100MΩ or more with DC 500 V |
| Dimensions | 305 (W) ?150 (H) ?400 (D) mm (344 ?165 ?459 mm, maximum dimensions) |
| Weight | Approx. 9.9 kg |
| Operating environment (indoor use only) | |
| Altitude | Below 2000 m |
| Overvoltage category | II |
| Pollution | 2 |
| Operating temperature/humidity | 0 to 40癈, below 85% |
| Storage temperature/humidity | - 20 to 70癈, below 85% |
| Accessories | Probe (?2) PC-51: 10 MΩ ?2%, 12.5 pF ?10%, 1/10 Operation Manual (1) Adjusting screwdriver (1) Power cable (1) |
| Applicable standard | |
| Safety standard | EN61010-I & A2 (1995) |
| EMI | EN55011 (1991) CLASS B FCC47CFR, PART15, SUBPART B, CLASS B |
| Immunity | IEC801-2 (1991) 8k VAD IEC801-3 (1984) 3V/m EIC801-4 (1988) |
| Options |
| OUTPUT | Makes possible mounting of optional IF-10 or IF-20R (but simultaneous mounting is not possible) |
| IF-10 | GP-IB interface (complies with IEEE-488 1978) |
Operation | Plots out the screen waveform and screen readout data to the GP-IB interface plotter. (TALK ONLY, HP-GL command) Outputs and inputs screen numerical data and outputs screen readout data through GP-IB interface computer. (TALK/LISTEN) |
| IF-20R | EIA RS-232C interface |
Operation | Plots out the screen waveform and screen readout data to the RS-232C interface plotter. (HP-GL command) Outputs and inputs screen numerical data and outputs screen readout data through RS-232C interface. Prints out screen waveform and screen readout data with an RS-232C printer (only with the model DPU-412 available from SII (Seiko Instruments)). Outputs and controls panel setup data. |
| Baud rate | 9600/1200 bps |
| Transfertype | Data length: 8 bits. Parity: none. Stop bit: 1 bit or more. Delimiter: CR LF Handshake: CTS-RTS |
| RT-5371 | Remote Controller |
Operation | Program step up/down/reset |